Skip Ribbon Commands
Skip to main content

NIH Websites Are Changing

Because of a lapse in government funding, the information on this website may not be up to date, transactions submitted via the website may not be processed, and the agency may not be able to respond to inquiries until appropriations are enacted. The NIH Clinical Center (the research hospital of NIH) is open. For more details about its operating status, please visit cc.nih.gov. Updates regarding government operating status and resumption of normal operations can be found at opm.gov.

ORF Home > Technical Resources > Bioenvironmental Studies > Ventilation Design Handbook on Animal Research Facilities Using Static Microisolators - Volumes I and II

Ventilation Design Handbook on Animal Research Facilities Using Static Microisolators - Volumes I and II

Ventilation Design Handbook on Animal Research Facilities Using Static Microisolators VOLUME I Book Cover Principal Investigator: Farhad Memarzadeh
Division of Technical Resources
Office of Research Services
National Institutes of Health
Bethesda, Maryland
September 1998
 Ventilation Design Handbook on Animal Research Facilities Using Static Microisolators VOLUME Il Book Cover

 

Table Of Contents
      Volume I
      Section I: INTRODUCTION PDF file - PDF (533KB) 508
      • Objectives
      • Background to Project
      • Literature Review
      • Project Summary
      Section II: ANIMAL ROOM VARIATIONS PDF file - PDF (1.5MB) 508
      • Outline of CFD Baseline Model
      • Whole Room Configurations
      • How the Data is Presented

      Section III: EVALUATION OF RESULTS AND RECOMMENDATIONS PDF file - PDF(3.3MB) 508 
      • Results for 101 Room Simulations
      • NH3 Concentrations for 10 Day Cycle
      • Ranking of Whole Room Simulations
      • Recommendations

      Section IV: EXPERIMENTAL WORK AND VERIFICATION OF THE CFD METHODOLOGY PDF file - PDF (3MB) 508 
      • Experimental Work
      • CFD Simulations and Validation Against Experimental Data

      Section V: CFD METHODOLOGY PDF file - PDF (661KB) 508 
      • Methodology Overview
      • Description of Mathematical Model
      • Nomenclature

      Section VI: STATISTICAL ANALYSIS PDF file - PDF (236) 508 
      • Introduction to Tests of Significance

      Section VII: GLOSSARY OF TERMS PDF file - PDF (252KB) 508 
      • Experimental Terms
      • CFD Glossary

      Section VIII: REFERENCES PDF file - PDF (69KB) 508 

      Appendix I: EXPERIMENTAL PROCEDURES AND DATA PDF file - PDF (5.6MB) 508 
      • Introduction
      • Cage Conditions
      • NO2, NH3, H2O and Heat Generation at High and Low Humidities
      • Room Condition
      • Photographs from Experimental Tests


       


      Volume II: SIMULATION DATABASE
      Volume II: Front page

      Part 1 of 4 PDF file - PDF (2.7MB) 508
      Part 2 of 4 PDF - PDF (2.3MB) 508
      Part 3 of 4 PDF file - PDF (2.7MB) 508
      Part 4 of 4 PDF file - PDF (2MB) 508
      • Introduction
      • Summary of Results of Whole Room Runs
      • Rankings of Results of Whole Room Runs
      • Whole Room Simulation Database

       

       

       

       
      This page was last updated on Nov 27, 2012